OPTIMUM OPERATING FACILITY

MISSION CRITICAL FACILITIES

From high density computing server rooms to the latest cloud storage data centers, these high-tech facilities present unique challenges with robust HVAC cooling systems, ultra-redundant power systems, and unique fire-suppression requirements.  

Throughout our history, Engineered Air Balance has completed numerous projects in mission critical facilities for private corporations and public clients alike.

Our team has the technical knowledge and expertise to perform HVAC TAB and building commissioning of the MEP systems in these challenging facilities. Dedicated to ensuring comfort, we will work to find a solution to meet your unique needs, no matter how complex. 

Facebook Fort Worth Data Center

Facebook Fort Worth Data Center

The Facebook Data Center is a 2,500,000 square foot campus located in Fort Worth, Texas, consisting of six buildings housing 22 data halls, a cold-storage facility, three administration areas, two central plants, and ten industrial water plants.

With passionate integrity, our team performed the Testing and Balancing of the HVAC systems, sensor calibration verification and control sequence verification. 

Notably, Facebook has one of the largest fan array air delivery systems EAB has ever had the pleasure of testing. Each hall has a built-up system consisting of 12 fan arrays of 15 fans each (180 fans) delivering approximately 1,270,000 cubic feet per minute. During the project, EAB developed special testing procedures for supply airflow, return airflow, and piping failure testing for ECH coils. Our team also developed a special field-testing apparatus that houses a set of flow stations and fits over individual fans in the fan array. 

Due to the overwhelming success of our testing procedures at Facebook Fort Worth Data Center, similar testing has been adopted at other mission critical sites around the country. Our dedication to integrity, quality, consistency, and teamwork delivered this successful result, and continues to grow our passion and knowledge of Total System Balancing. 

Facebook Fort Worth Data CenterFacebook Fort Worth Data Center

The Facebook Data Center is a 1,364,000 square foot facility located in Fort Worth, Texas, consisting of four data halls, a core area, central plant, and two industrial water plants. 

With passionate integrity, our team performed the Testing and Balancing of the HVAC systems, control point and sensor calibration verification and control sequence verification. 

Notably, Facebook has one of the largest fan array air delivery systems EAB has ever had the pleasure of testing. Each hall has a built-up system consisting of 12 fan arrays of 15 fans each (144 fans) delivering approximately 1,250,000 cubic feet per minute. During the project, EAB developed special testing procedures for supply airflow, return airflow, and piping failure testing for ECH coils. Our team also developed a special field-testing apparatus that houses a set of flow stations and fits over individual fans in the fan array. 

Due to the overwhelming success of our testing procedures at Facebook Forth Worth Data Center, similar testing has been adopted at other mission critical sites around the country. Our dedication to integrity, quality, consistency, and teamwork delivered this successful result, and continues to grow our passion and knowledge of Total System Balancing. 